โšก Restriction Orifice Sizer

Size thick-plate single or multi-hole restriction orifices (ISO 5167 / Crane TP410) for permanent pressure dissipation and cavitation check.

โšก Fortran 90 Engine Double Precision (IEEE 754) โœ“ ISO / ASME Validated
Restriction Orifice Sizer Fluid Mechanics
๐Ÿ“Š Solver Telemetry โ— ACTIVE
๐Ÿ‘๏ธ Views 28
โšก Solves 23
๐Ÿ’พ Downloads 465 ๐Ÿ“ฆ Fortran Code 4.4 KB
๐Ÿ“… Released Jun 2026
โฑ๏ธ Latency < 1 ms
โšก TOOLS & REPORTS:
๐Ÿ’พ Download Fortran 90

โšก Thick-Plate Restriction Orifice Jet & Pressure Recovery

Real-time visual simulation of vena contracta jet contraction & permanent head loss

๐Ÿ“ Configuration & Presets

๐Ÿ’ง Pump Recirc (ฮ”P=20 bar) ๐Ÿ”ฅ Fuel Gas (ฮ”P=2.5 bar) โ„๏ธ Chilled Water (ฮ”P=1.2 bar) โ™จ๏ธ Multi-Hole Blowdown (55 bar)
โš™๏ธ Fluid & Pipe Flow Rate
โšก Pressures & Restriction Drop
Used to verify cavitation index ฯƒ
Multi-hole plates reduce noise & cavitation
Restriction Orifice Formulations:
โ€ข Permanent Loss Ratio: ฮ”Pperm / ฮ”Po = 1 โˆ’ ฮฒ1.9
โ€ข Orifice Flow: Q = Cd ยท Ao ยท โˆš[ (2 ฮ”Po) / ฯ ] / โˆš(1 โˆ’ ฮฒโด)
โ€ข Cavitation Index: ฯƒ = (Pโ‚‚ โˆ’ Pv) / ฮ”Pperm
โ€ข Plate Thickness: tmin = do ยท โˆš[ (3 ฮ”P) / (4 Sallow) ]

๐Ÿ“Š Restriction Sizing Results

๐Ÿ“Š Output Summary
๐Ÿ’พ Fortran Source

Calculated Orifice Bore Hole Size
do = 11.56 mm
Diameter Ratio: ฮฒ = 0.1445 (d/D)
Plate Thk = 1206 mm
Cavitation Index (ฯƒ) 0.25 ๐Ÿšจ SEVERE CHOKED CAVITATION / FLASHING
Downstream Pressure (Pโ‚‚) 5.00 bar(a) Permanent Loss = 20.00 bar
Orifice Bore Area 105.0 mmยฒ 1 hole(s) ร— 105.0 mmยฒ
Volumetric Flow Rate (Q) 15.03 mยณ/h Discharge Cd = 0.62

๐Ÿ“ˆ Orifice Bore Hole (do) vs Permanent ฮ”P

๐Ÿ“‰ Cavitation Index (ฯƒ) vs Pressure Drop

=================================================================
 THERMOFLUIDCALC โ€” THICK-PLATE RESTRICTION ORIFICE REPORT
=================================================================
Case Title                 : Centrifugal Pump Minimum Flow Recirculation Orifice
Pipe Inside Diameter (D)   : 80.00 mm
Mass Flow Rate (W)         : 15,000.0 kg/h
Upstream Pressure (P1)     : 25.00 bar(a)
Downstream Pressure (P2)   : 5.00 bar(a)
Permanent Pressure Loss    : 20.00 bar (2000.00 kPa)
Number of Orifice Holes    : 1
-----------------------------------------------------------------
ORIFICE BORE DIAMETER (do) : 11.562 mm each
Diameter Ratio Beta (d/D)  : 0.1445
Cavitation Index (Sigma)   : 0.248 (๐Ÿšจ SEVERE CHOKED CAVITATION / FLASHING)
Recommended Plate Thickness: 1206.0 mm
=================================================================

๐Ÿ“˜ Calculation Methodology & Crane TP410 Standards

Permanent Pressure Loss Recovery

Unlike flowmeter orifices, restriction orifices are sized for permanent non-recoverable pressure dissipation based on Crane TP410 loss ratio:

ฮ”Pperm / ฮ”Po = 1 โˆ’ ฮฒ1.9

Cavitation Index & Multi-Hole Plates

When $\sigma < 1.5$, severe cavitation erosion risks arise. Splitting the flow across multiple small holes or multi-stage plates elevates cavitation resistance.

Key Engineering Assumptions

  • Square-edged thick restriction orifice plate ($t \ge 0.05 D$).
  • Discharge coefficient $C_d = 0.62$ in high Reynolds turbulent flow.
  • Stainless steel 316 / Monel plate bending stress limit per ASME Section VIII.